ventilator with wheel 

Payment Terms: T/T 
Place of Origin: Zhejiang, China (Mainland) 
inquire
Add to My Favorites
HiSupplier Escrow
Share |

Product Detail

Model No.: 600660A
Packing: CASE
Brand Name: LifeCare
Certificate: CE ,ISO9001, 13485
Means of Transport: BY SEA /BY AIR
Delivery Date: 20 DAYS
Function: MEDICAL USE
Export Area: EUROPE /ASIA /SOUTH AMERICA

Be controlled by microprocess; Invasive and Non-invasive ventilation; End-inspiratory holding function; Electronic controlled gas-oxygen blender.


Main Feature:

Be controlled by microprocess.
Gas driven electronically controlled.
Used for adult and pediatric.
Colour TFT display + LED display.
Invasive and Non-invasive ventilation
PEEP function, Adjusted by electronic controlling system, make it high accurate and more stable.
CPAP function
End-inspiratory holding (inhalation platform, end-inhalation pause) function.
SIGH function
I/E function
Compliance compensated function.
Electronic controlled gas-oxygen blender.


MAIN TECHNICAL PARAMETER:



Mode: IPPV, IPPV+SIGH, A/C(SIPPV), SIMV, PCV, PSV, SIMV+PSV, SPONT, MANU.
Tidal volume: 50—1500mL.
Frequency: 6-60/min
Inhalation time: 0.2~8s (I/E 2:1~1:5)
Power: ~220V±10% 50Hz±2%
Holding time: 0~3s
Controlling pressure: 1.0~6.0kpa.
PSV level: 0~5.0kpa.
PEEP/CPAP level: 0~2.0 kpa.
Inhalation trigger: -2.0~+2.0kpa.
SIGH time: 1-5 times( every 100 times)
Oxygen concentration:21%~100% (continual adjustable)
Ventilation parameter monitoring:
Tidal volume, minute ventilation, frequency, inhalation time, airway peak pressure, airway average pressure, PEEP, O2 concentration, Time-airway pressure waveform, Time- flow waveform, trigger indicate.
Alarm:( Audio-visual)
No tidal volume(asphyxia), minute ventilation is too high(low), airway pressure is too high(low), oxygen or air is not full, frequency is too high (when in SPONT), AC power off, Back-up battery voltage is too low.
Power off:
There will be audio and visual alarm indicates when power is off in unusual way, and the power will be supplied by back-up battery( battery working time≥3 hours).
Gas resource: oxygen or depurative air. The given working pressure is 0.4±0.1Mpa.
bigPhoto
 Mr. David Hee

Tel: 86-574-87255354
Fax: 86-574-87125894
Contact to this supplier

Didn't find what you're looking for? Post Buying Lead or contact HiSupplier Customer Service Center  for help!

Related Search

Find more related products in following catalogs on Hisupplier.com

Company Info

Lifecare Medical Equipments Co., Ltd. [China (Mainland)]


Business Type:Manufacturer, Trading Company
City: Ningbo
Province/State: Zhejiang
Country/Region: China (Mainland)

You May Like: