Product Detail
Model No.:
600144
Packing:
case
Brand Name:
LifeCare
Export Area:
Europe,USA,Middle East,Asia
Means of Transport:
By sea or by air
Delivery Date:
10days
Certificate:
CE,ISO,FDA
Min. Order:1 UNT;Packing:case;Transportation:By sea or by air;DeliveryDate:10days;PaymentType:T/T or L/C AT SIGHT;Trademark:LifeCare;Certificate:CE,I
Working conditions
Ambient temperature: +5℃~40℃
Relative Humidity:93%
Atmospheric pressure:860 hpa-1060pa
Power voltage:220V±10%,50H±1HZ
Rated Power:≤400W
Technical parameters
1.Consecutive work:≥8 hours;
2.Lead:Common Computer Editing used 16 different path leads;
3.Paper Running:15mm/s,30mm/s,error±10%;
4.Sensitivity(plus):10μV/mm,20μV/mm,50μV/mm;
5.Common-mode suppression ratio:≥80db;
6.Internal Noise Amplifier:≤3μV/p-pO;
7.Amplitude frequency characteristics:(1-30)Hz,error±5%~ -30%;
8.Frequency Sub:(0.5-30),Scope δ、O、β1、β2?six segment;
9.Polarization voltage tolerance:DC polarization voltage increases +300mv,Sensitivity is less than 10%;
10.Low frequency Characteristics:(0.5,1.6,5.0)Hz(Equivalent to the time constant:0.3,0.1,0.03) Three item,extent descend≥30Db;
11.High frequency Characteristics:(15,30)Hz Two item,extent descend≥3Db;
12.Calibration voltage:50μV sine wave,error±5%;
13.Baseline drift≤1.1mm.
Features
1.Print quality report format options, fonts, and colors can set their own;
2.Perfect free T EEG hodoscope,Intelligent Computer Control;With statistical charts and install function,The rich and Template Library;Two levels Isolation System,Prevent leakage,Ensure safety;Adaptive Automatic Calibration System,EEG acquisition to ensure accurate distortion;Four time constants and arbitrary combinations of hardware filtering parameters;Show speed(Paper Running speed) Three levels,Show extent twenty levels;
3.Open Eyes,Closed Eyes,dormancy,hyperventilation,Adequate eruption electric potential,Describe the various incidents,EEG amplification roaming full screen;
4.All kinds of paper-speed and Gain Control;Artificial,Automatic Frequency NC photic stimulation;
5.Monopole,Double stage and reference electrode is free to set;
6.Absolute, relative of the six pieces,Display topographical maps and associated with EEG,Digital Map,Probability map,Side-glance map,Enlarged map,Left View map,Right View map,Top View map,Ratio detection;
7.Three-dimensional topographic map rotation,Real-time compression of a variety of power spectra;
8.WINDDOWS interface in Chinese,Mouse bid operation and the function button handle;
9.Images are free to choose the reporting format,may revise arbitrarily together,has rich case form board warehouses built-in;
10.16 steps of relief maps with layers,three-dimensional revolution relief map,Several rotating simultaneously with a single amplification rotating text of the report can store more than one million copies;
11.Hot line period of time brain wave real time scanning, at the same time precis writer patient parameter, instrument job parameter, timing, lead couplet name, various indicia sign, colour screen surveillance, relief map, power spectrum nalytical,number be placed in analytical, compress fair amount of confidence analytical, parameter measurement, store up,replay;
12.Software lifelong escalate for free.